Quick Inquiry

Tell us what you need — we reply promptly.

November 26, 2026 · By the LINEX Battery Team

Power Station Runtime at 50% vs 100% Load

Quick Summary: A 1,000Wh LiFePO4 station runs about 1.4 hours at 500W and 0.7 hours at 1,000W after 80% depth of discharge and 90% inverter efficiency. Lead-acid stations fall faster at full load because Peukert losses cut usable capacity. Compare runtime at both points, not just the watt rating.
D1000Li 1,000W portable power station with a 1,000Wh LiFePO4 battery

Runtime is usable Wh divided by load, then adjusted for losses

A power station’s runtime equals its usable DC watt-hours multiplied by inverter efficiency and divided by the AC load. A 1,000Wh LiFePO4 station at 80% depth of discharge gives 800Wh of DC energy; at 90% inverter efficiency, about 720Wh reaches the AC outlet. That is the number to divide by the load, not the 1,000Wh label.

AC load Share of rated output Runtime from 720Wh usable
100W 10% 7.2h
250W 25% 2.9h
500W 50% 1.4h
750W 75% 1.0h
1,000W 100% 0.7h

The table assumes a 1,000W rated station and a constant 90% inverter efficiency. Real efficiency changes with load, temperature and waveform, so treat the numbers as a planning estimate and confirm the full-load case with a test.

The 50% point usually returns more than half the runtime

An inverter is not equally efficient at every load. Many designs peak around 40% to 70% of rated output, while a 100% load adds heat and voltage sag. A 1,000W station that runs 1.4 hours at 500W may run slightly less than 0.7 hours at 1,000W, because the full-load case loses more energy as heat.

Model Chemistry Capacity Rated output 50% load runtime 100% load runtime
EG009Li LiFePO4 256Wh 300W 1.2h at 150W 0.6h at 300W
EG007Li LiFePO4 460.8Wh 500W 1.3h at 250W 0.7h at 500W
D1000Li LiFePO4 1,000Wh 1,000W 1.4h at 500W 0.7h at 1,000W
B500 Lead-acid 600Wh 500W 1.1h at 250W 0.5h at 500W
B3000 Lead-acid 2,400Wh 3,000W 0.7h at 1,500W 0.4h at 3,000W

The LiFePO4 rows use 80% depth of discharge and 90% inverter efficiency. The lead-acid rows use 50% depth of discharge and the same 90%. The lead-acid figures are upper bounds because Peukert losses rise at high current.

Lead-acid loses capacity faster at high current

Peukert’s law describes how a 12V 50Ah lead-acid block loses usable capacity as discharge current rises. The block holds 600Wh on paper, but at a 500W AC load the DC draw is about 556W, or 46A at 12V, which is close to a 1C rate for a 50Ah block. The linear 0.5-hour estimate is an upper bound, not a test result.

Load on the B500 DC current at 12V Linear runtime Real tendency
250W 23A 1.1h Close to linear
500W 46A 0.5h Shorter than linear

The gap grows with age and temperature. A lead-acid block that has lost 20% of its capacity also loses voltage faster under load, so the inverter reaches its low-voltage cutoff before the calculated watt-hours are used.

LiFePO4 holds voltage and capacity closer to the linear line

A LiFePO4 pack has lower internal resistance than a lead-acid block, so at a 1,000W load its terminal voltage stays above the BMS cutoff and the runtime ratio stays closer to the energy ratio. The D1000Li stores 1,000Wh, the EG007Li stores 307.2Wh to 460.8Wh, and the EG009Li stores 204.8Wh or 256Wh, all in LiFePO4 cells.

Chemistry Depth of discharge used here Why
LiFePO4 80% Keeps a margin above the BMS cutoff and supports the published cycle life
Lead-acid 50% Deep cycling shortens service life

The 80% figure is a planning assumption, not a hard BMS limit. A LiFePO4 station can run deeper, but the last 10% to 20% sits at a lower voltage and gives less warning before cutoff.

Modified sine wave changes the safe 100% load

The EG009Li and D1000Li list a modified sine wave inverter, while the B500, EG007Li and B3000 list pure sine wave. A modified sine wave can run heaters and simple power supplies, but motors, compressors and some chargers draw extra current and heat at the same watt rating. That makes the 100% load point less useful for those appliances.

Model Waveform Loads that fit Loads to check
EG009Li 300W Modified sine wave Phones, lights, fans, small power supplies Motors and compressors
D1000Li 1,000W Modified sine wave Resistive loads, tools with universal motors Fridges and sensitive electronics
B500 500W Pure sine wave Fridges, electronics, small pumps High-surge motors
EG007Li 500W Pure sine wave Sensitive electronics and small appliances High-surge motors
B3000 3,000W Pure sine wave Power tools and appliances within 3,000W Large motor starts

A 100% load test on a modified sine wave station can trip a compressor that the same wattage would run on a pure sine wave unit. Check the appliance’s starting surge and waveform requirement before using the full rating.

Sourcing LiFePO4 batteries for your market?LINEX supplies 12V-48V lithium batteries, ESS and solar kits - wholesale, OEM/ODM, flexible MOQ.

A load list beats a single 50% or 100% number

A load list for a camping day totals each appliance’s watts, hours and duty cycle, then divides the total by usable Wh; the example below comes to 570Wh. It uses a 10W phone charger for 2 hours, a 10W LED light for 4 hours, a 60W laptop for 3 hours, a 45W fridge at 50% duty for 8 hours and a 30W fan for 5 hours.

Device Watts Hours Duty Energy
Phone charger 10W 2h 100% 20Wh
LED light 10W 4h 100% 40Wh
Laptop 60W 3h 100% 180Wh
Fridge 45W 8h 50% 180Wh
Fan 30W 5h 100% 150Wh
Total 570Wh

Add 15% for cold, aging and inverter losses, and the day needs about 656Wh. The D1000Li’s 720Wh usable covers it with a small margin; a 500Wh station does not. The same load list shows why a single 50% or 100% runtime number cannot answer a mixed-load question.

Recharge time sets the daily duty cycle

A station that runs for 1.4 hours but needs 6 to 8 hours to recharge cannot cover a full day of the same load without a second pack or a larger solar array. The B500 reaches 80% after 8 hours on its built-in 14.4V 5A charger, the EG007Li reaches 80% after 6 hours, and the B3000 accepts 36V 500W of solar input.

Model AC recharge Solar input Battery
B500 80% after 8 hours 15V to 40V, 200W max 12V 50Ah
EG007Li 80% after 6 hours 15V to 20V, 90W max 12.8V 24Ah to 36Ah
B3000 Not listed 36V, 500W max 24V 100Ah

A 200W solar panel does not deliver 200W all day. Plan on 4 to 6 productive hours and match the panel to the station’s input limit, not to its battery capacity.

Where the LINEX portable range fits

The LINEX portable range runs from 100W to 3,000W, and the portable power station sizing guide turns a load list into watt-hours and adds the inverter margin. The B3000 3,000W station uses a 24V 100Ah lead-acid bank and a pure sine wave output. The D1000Li 1,000W station uses a 1,000Wh LiFePO4 pack, and the B500 500W station and EG009Li 300W station cover smaller loads. The portable power station supplier page lists the full range.

Frequently asked questions

Does a 1,000W station run twice as long at 500W as at 1,000W?

Roughly, yes for a LiFePO4 pack. The exact ratio depends on inverter efficiency, temperature and the battery’s cutoff voltage. At 100% load the inverter produces more heat, so the full-load runtime is usually a little shorter than half the 50% runtime.

Why does my power station cut off before the calculated runtime?

The calculation uses a fixed inverter efficiency and a fixed depth of discharge. Real runtime falls when the battery is cold, aged or at a high load, and when the inverter reaches its low-voltage cutoff early. A load with a high starting surge can also trip the output before the watt-hours are used.

Is 50% load better for battery life?

A lower continuous load means less heat and less voltage sag, which helps both chemistries. For LiFePO4, the cycle life rating already assumes a defined depth of discharge, so 50% load does not double the cycle count. For lead-acid, avoiding deep discharge matters more than the load percentage.

Can I run a fridge at 100% load?

Only if the station’s continuous rating covers the fridge’s running load and its surge rating covers the compressor start. A fridge cycles, so its average load is lower than its peak. Check the surge figure and use a pure sine wave station for a compressor.

How do I convert watt-hours to runtime?

Divide usable watt-hours by the AC load in watts. For a 1,000Wh LiFePO4 station, 80% depth of discharge and 90% inverter efficiency leave 720Wh; at 500W that is 1.4 hours, and at 1,000W it is 0.7 hours.

Sources: LINEX product pages: D1000Li 1,000W (1,000Wh LiFePO4, modified sine wave, MPPT, checked 2026-11-26); EG009Li 300W (204.8Wh or 256Wh, modified sine wave, checked 2026-11-26); EG007Li 500W (307.2Wh to 460.8Wh, pure sine wave, >90% conversion efficiency, checked 2026-11-26); B500 500W (12V 50Ah lead-acid, pure sine wave, >90% conversion efficiency, 80% after 8 hours, checked 2026-11-26); B3000 3,000W (24V 100Ah lead-acid, pure sine wave, 36V 500W solar input, checked 2026-11-26); portable power station sizing guide (load list method, checked 2026-11-26); Wikipedia Peukert’s law (capacity fall at high discharge current, checked 2026-11-26); Wikipedia Lithium iron phosphate battery (chemistry and voltage behavior, checked 2026-11-26). Last updated 2026-11-26.

✆WhatsApp ✉Email ↑Top