Quick Inquiry

Tell us what you need — we reply promptly.

IP65 Outdoor Telecom Battery Cabinet

The LINEX IP65 outdoor telecom battery cabinet protects batteries, rectifiers and network equipment at base stations and remote sites. Available from 6U to 26U, it combines a 19-inch four-post rack, galvanized cold-rolled steel, 45mm EPS insulation and a sealed weatherproof enclosure. Adjustable brackets, door-controlled lighting, temperature-controlled exhaust cooling and configurable locks support roadside, railway, smart-city and industrial telecom installations. Final cooling and internal layout are configured to project conditions.

Quick Summary: The IP65 Outdoor Telecom Battery Cabinet is a weatherproof 19-inch equipment enclosure for telecom batteries, rectifiers and network hardware. It is available in 6U-26U sizes with 600 × 450mm or 600 × 600mm footprints, galvanized steel, 45mm EPS insulation, adjustable brackets and configurable cooling and door options.

Key Features

  • ✓IP65 sealed protection against weather, dust and insects
  • ✓6U to 26U capacity for different site layouts
  • ✓19-inch four-post square-hole rack with adjustable brackets
  • ✓Galvanized cold-rolled steel with 45mm EPS insulation
  • ✓600 × 450mm and 600 × 600mm footprint options
  • ✓Temperature-controlled exhaust fan and project cooling options
  • ✓Mechanical lock standard with electronic and double-door options
  • ✓OEM configuration for internal layout, color and project labeling

Technical Specifications

Product NameOutdoor Telecom Cabinet
Capacity (U)6U, 9U, 12U, 15U, 18U, 20U, 26U
Rack Standard19 inch, 4-post square-hole, 3 pairs adjustable brackets
Dimensions (W*D)600*450mm, 600*600mm (Height varies by U size)
MaterialGalvanized cold-rolled steel + 45mm EPS insulation
Protection DegreeIP65 (Weatherproof, dustproof, insect-proof, UV-resistant)
Cooling SystemAC power redundancy; temperature-controlled exhaust fan (600W for 650mm cabinet, 1500W for ≥750mm cabinet)
Door ConfigurationFront single door with mechanical lock (Standard); Optional front+rear double doors with brand electronic lock
Smart InteriorDoor-controlled LED light, temperature-controlled fan, full installation hardware
Application5G base stations, outdoor telecom rooms, roadside cabinets, railway/subway lines, renewable energy sites, smart city infrastructure, industrial IoT gateways

Common FAQs

Which equipment can be installed in this outdoor telecom cabinet?

The cabinet can house compatible telecom batteries, rectifiers, power distribution, controllers and network equipment within a 19-inch rack layout. Final equipment selection depends on U height, depth, heat load, cable entry, maintenance clearance and the total supported weight of the configured cabinet.

Which cabinet sizes are available?

Available capacities are 6U, 9U, 12U, 15U, 18U, 20U and 26U. Standard footprint options are 600 × 450mm and 600 × 600mm, while cabinet height varies with U capacity. Confirm equipment dimensions and service clearance before selecting a size.

What does the IP65 protection rating cover?

The enclosure is specified as IP65 for protection against dust and water exposure, with a sealed structure designed for outdoor telecom use. Site design must still consider cable glands, door sealing, drainage, installation orientation, flooding risk, corrosive atmosphere and maintenance practices.

How is cabinet temperature controlled?

The cabinet includes temperature-controlled exhaust cooling and supports project-specific cooling arrangements. Cooling capacity must be selected from ambient temperature, solar load, installed equipment heat, insulation, cabinet size and operating duty. Fan, air-conditioning or heater requirements should be confirmed during engineering review.

Can the cabinet be used in hot, humid or coastal locations?

It can be configured for demanding outdoor sites, but temperature, humidity, salt spray, corrosion, UV exposure and ventilation must be reviewed for each project. Provide the installation location and environmental range so coating, sealing, thermal management and maintenance requirements can be confirmed.

How are batteries and power equipment mounted inside?

The cabinet uses a 19-inch four-post square-hole rack with three pairs of adjustable brackets. The internal layout must account for battery weight, shelf support, rectifier and distribution space, cable bend radius, grounding, airflow, alarms and safe front or rear maintenance access.

Which lock, door and monitoring options are available?

A front single door with mechanical lock is standard. Electronic locks and front-and-rear double-door arrangements are available as project options. Door-controlled LED lighting, temperature-controlled fan operation and alarm or monitoring interfaces should be specified during configuration review.

What information is required for an outdoor cabinet quotation?

Provide the required U size, cabinet depth, installed equipment list, battery quantity and weight, heat load, ambient temperature, cooling preference, cable entry, door and lock arrangement, monitoring interfaces, color, project quantity and destination. These details are needed before confirming the final configuration.

Telecom Project Resources

Use these resources to plan the battery, rack layout, cooling and integration details required for an outdoor telecom cabinet quotation.

Why Source From LINEX

Project-Based Configuration Cabinet size, internal layout, color and labeling can be reviewed against the confirmed equipment list.
IP65 Outdoor Protection Sealed galvanized-steel construction with 45mm EPS insulation for outdoor telecom installations.
Cooling & Access Options Exhaust cooling, door arrangement and lock options are selected from site and maintenance requirements.
Configuration Checked Before Shipment Key dimensions, rack capacity and confirmed project options are checked against the approved configuration.
✆WhatsApp ✉Email ↑Top