Quick Inquiry

Tell us what you need — we reply promptly.

Standard 48V 50Ah LiFePO4 Battery for Telecom Sites

The Standard 48V 50Ah telecom LiFePO4 battery is a compact 2.4kWh rack-mounted module for base stations, remote sites, network backup and compatible UPS systems. It supports up to 50A charge and discharge at 25°C, with RS485/RS232 communication for monitoring and integration. Built-in BMS protection, Grade-A EVE or CATL cells, a 6,000-cycle rating at 80% DOD and a 29kg enclosure suit space-constrained telecom projects.

Quick Summary: The Standard 48V 50Ah is a compact 2.4kWh rack-mounted LiFePO4 battery for telecom base stations, remote sites and UPS backup. It supports up to 50A charge and discharge at 25°C, provides RS485/RS232 communication, and measures 483 × 325 × 133mm at 29kg for space-constrained project integration.

Key Features

  • ✓2.4kWh nominal energy at 48V and 50Ah
  • ✓Up to 50A charge and discharge at 25°C
  • ✓Compact 483 × 325 × 133mm rack enclosure
  • ✓RS485 and RS232 communication for site monitoring
  • ✓BMS protection for temperature, current, short circuit and over-discharge
  • ✓6,000-cycle rating at 80% depth of discharge
  • ✓Charge from 0°C to 65°C and discharge from -20°C to 65°C
  • ✓Grade-A EVE or CATL LiFePO4 cells

Technical Specifications

Model48V50AH
Anode / Cell TypeLiFePO4
Nominal Voltage48Vdc
Nominal Capacity50Ah
Nominal Energy2400Wh
Equalization Charge Voltage53.3Vdc
Floating Charge Voltage51.0Vdc
Cutoff Discharge Voltage40.5Vdc
Max Charge / Discharge Current50A / 50A @25℃
Installation MethodRack Mounted
Weight29 kg
Size (WDH)483mm325mm133mm
Self Discharge @25℃< 5% in 90-day storage
CommunicationRS485, RS232
Protection FunctionsOver-temperature, over-current, short circuit, over-discharge, etc.
Cycle Life6000 cycles (80% DOD)
Operating TemperatureCharge: 0℃~65℃; Discharge: -20℃~65℃
Relative Humidity5% ~ 95%
Altitude0 ~ 6000m

Common FAQs

What capacity and applications does this 48V 50Ah telecom battery support?

The battery provides 2.4kWh of nominal energy for compact base stations, remote telecom nodes, network backup and compatible UPS systems. Select battery quantity from measured site load, required backup duration, usable depth of discharge, system losses, temperature and capacity-aging reserve.

How is backup time calculated for a 48V 50Ah battery?

Multiply the average site load by the required backup hours, then account for usable system efficiency, depth of discharge, temperature, cable losses and aging reserve. Actual runtime depends on the complete load profile and cannot be determined from the 50Ah rating alone.

What rack space and support are required?

The rack-mounted module measures 483 × 325 × 133mm and weighs 29kg. Confirm rack width, depth, vertical clearance, load capacity, ventilation, cable routing and service access before installation. The supporting structure must carry the battery safely during operation and maintenance.

Is it compatible with an existing telecom rectifier or UPS?

Check the charging profile against 53.3V equalization, 51.0V float and 40.5V discharge cutoff. Also verify charge-current limits, low-voltage disconnect settings, cable size, protection devices and communication requirements. Nominal 48V alone does not confirm compatibility.

Can multiple 48V 50Ah batteries be connected in parallel?

Parallel expansion requires an engineering review of battery configuration, state of charge, communication settings, busbars, cable lengths, current sharing and overcurrent protection. Provide the planned quantity, rectifier details and site load so the proposed architecture can be checked.

Does the battery support remote monitoring?

RS485 and RS232 communication are available for integration with compatible site controllers, rectifiers or monitoring systems. Confirm the protocol, connector, register map and alarm requirements during project evaluation because the communication interface must match the site equipment.

Can it replace an existing lead-acid telecom battery?

Replacement is possible only after checking rack space, rectifier voltage, charging current, low-voltage disconnect, cables, fuses or breakers and monitoring requirements. Existing lead-acid and lithium configurations should not be mixed without validating system logic and protection coordination.

Which certification documents and warranty are available?

Documentation for UN38.3, CE, RoHS and FCC review is available, with a 5-year warranty. Confirm the exact documents required by the destination market and project tender before ordering, and include the application, quantity, installation environment and destination.

Telecom Project Resources

Use these resources to compare site configurations, estimate backup capacity, and prepare the technical details required for a 48V telecom battery quote.

Why Source From LINEX

Factory-Direct Wholesale OEM / ODM & private label support for importers and distributors.
5-Year Warranty Covered on every LiFePO4 battery we ship.
Certified Quality UN38.3 · CE · RoHS · MSDS on file for every model.
100% Tested Before Shipment Every unit capacity- and safety-tested before it ships.
✆WhatsApp ✉Email ↑Top