Quick Inquiry

Tell us what you need — we reply promptly.

48V 150Ah Telecom LiFePO4 Battery

The Standard 48V 150Ah telecom LiFePO4 battery is a 7.2kWh rack-mounted module for base stations, remote sites, network backup and compatible UPS systems. It supports up to 150A charge and discharge at 25°C, with RS485/RS232 communication for monitoring and integration. Built-in BMS protection, Grade-A EVE or CATL cells, a 6,000-cycle rating at 80% DOD and a -20°C to 65°C discharge range support demanding telecom projects.

Quick Summary: The Standard 48V 150Ah is a 7.2kWh rack-mounted LiFePO4 battery for telecom base stations, remote sites and UPS backup. It supports up to 150A charge and discharge at 25°C, provides RS485/RS232 communication, and includes BMS protection in a 482 × 440 × 178mm enclosure for system integration.

Key Features

  • ✓7.2kWh nominal energy at 48V and 150Ah
  • ✓Up to 150A charge and discharge at 25°C
  • ✓Rack-mounted 482 × 440 × 178mm enclosure
  • ✓RS485 and RS232 communication for site monitoring
  • ✓BMS protection for temperature, current, short circuit and over-discharge
  • ✓6,000-cycle rating at 80% depth of discharge
  • ✓Charge from 0°C to 65°C and discharge from -20°C to 65°C
  • ✓Grade-A EVE or CATL LiFePO4 cells

Technical Specifications

Model48V150AH
Anode / Cell TypeLiFePO4
Nominal Voltage48Vdc
Equalization Charge Voltage53.3Vdc
Floating Charge Voltage51.0Vdc
Cutoff Discharge Voltage40.5Vdc
Max Charge / Discharge Current150A / 150A @25°C
Installation MethodRack mounted
Weight60kg
Size (WDH)482mm440mm178mm
Self Discharge @25°C< 5% in 90-day storage
CommunicationRS485, RS232
Protection FunctionsOver temperature, over current, short circuit, over discharge, etc.
Cycle Life6000 cycles (80% DOD)
Operating TemperatureCharge: 0°C ~ 65°C; Discharge: -20°C ~ 65°C
Relative Humidity5% ~ 95%
Altitude0 ~ 6000m

Common FAQs

What capacity and applications does this 48V 150Ah telecom battery support?

The battery provides 7.2kWh of nominal energy for telecom base stations, remote sites, network backup and compatible UPS systems. Select the number of modules from measured site load, required backup duration, usable depth of discharge, system losses, temperature and the reserve required for capacity aging.

How is backup time calculated for a 48V 150Ah battery?

Multiply the site's average DC load by the required backup hours, then account for usable system efficiency, depth of discharge, temperature, cable losses and aging reserve. Actual runtime depends on the complete load profile and cannot be determined from the 150Ah rating alone.

What rack space and support are required?

This rack-mounted module measures 482 × 440 × 178mm and weighs 60kg. Confirm rack width, depth, vertical clearance, load capacity, ventilation, cable routing and service access before installation. The cabinet and shelf structure must support the battery safely throughout operation and maintenance.

Is it compatible with an existing telecom rectifier or UPS?

Check the charging profile against 53.3V equalization, 51.0V float and 40.5V discharge cutoff. Also confirm charge-current limits, low-voltage disconnect settings, cable size, protection devices and communication requirements. Nominal 48V alone does not confirm compatibility.

Can multiple 48V 150Ah batteries be connected in parallel?

Parallel expansion requires an engineering review of the battery configuration, state of charge, firmware, communication settings, busbars, cable lengths, current sharing and overcurrent protection. Provide the planned quantity, rectifier details and site load so the proposed architecture can be checked before installation.

Does the battery support remote monitoring?

RS485 and RS232 communication are available for integration with compatible site controllers, rectifiers or monitoring systems. Confirm the protocol, connector, register map and alarm requirements during project evaluation because the communication interface must match the equipment already used at the site.

Can it replace an existing lead-acid telecom battery?

Replacement is possible only after checking rack space, rectifier voltage, charging current, low-voltage disconnect, cables, fuses or breakers and monitoring requirements. Existing lead-acid and lithium configurations should not be mixed or staged without validating the power-system logic and protection coordination.

Which certification documents and warranty are available?

Documentation for UN38.3, CE, RoHS and FCC review is available, with a 5-year warranty. Confirm the exact documents required by the destination market and project tender before ordering, and include the intended application, quantity, installation environment and destination in the inquiry.

Telecom Project Resources

Use these resources to compare site configurations, estimate backup capacity, and prepare the technical details required for a 48V telecom battery quote.

Why Source From LINEX

Factory-Direct Wholesale OEM / ODM & private label support for importers and distributors.
5-Year Warranty Covered on every LiFePO4 battery we ship.
Certified Quality UN38.3 · CE · RoHS · MSDS on file for every model.
100% Tested Before Shipment Every unit capacity- and safety-tested before it ships.
✆WhatsApp ✉Email ↑Top