Quick Inquiry

Tell us what you need — we reply promptly.

November 11, 2026 · By the LINEX Battery Team

Warranty Terms for LiFePO4: What 5 Years Should Cover

Quick Summary: A five-year LiFePO4 warranty should name a capacity floor, cover the BMS and cells, and state who pays freight and labor. The term alone says little. A 5-year policy with a 70% floor and paid return freight is worth more than a 10-year policy with vague exclusions.
Five-year LiFePO4 warranty cover: capacity floor, BMS, freight and claim file

Five years is a term, not a coverage level

A five-year warranty on a LiFePO4 battery covers 60 months from a stated start date. At one full cycle per day, that is about 1,825 cycles. A 6,000-cycle pack is rated for roughly 16 years at the same rate, so the warranty ends long before the cycle-life rating. The gap matters because the warranty, not the cycle count, decides who pays for an early failure.

The start date is the first thing to check. A policy that starts on the shipment date can lose weeks before the battery reaches a project site, and longer if the pack sits in storage. A policy that starts on delivery or commissioning gives the buyer the full term. The difference is small on a 12V pack and large on a rack bank with a multi-month build schedule.

A usable policy names a capacity floor and a test method

Capacity fade is normal. The question is where the policy sets the floor. A 100Ah battery at 70% still delivers 70Ah; at 80% it delivers 80Ah. On a 12V 100Ah pack rated at 1,280Wh, those floors equal 896Wh and 1,024Wh at nominal voltage. Without a stated C-rate, temperature and cutoff, the number cannot be tested the same way twice.

LINEX publishes a 5-year limited warranty that covers “capacity dropping below 70% of the rated value” under normal use. The floor is explicit. The policy does not publish a test procedure, so the method should be agreed in the purchase contract: a 0.2C discharge at 25°C, starting from a full charge, with the start and end voltages recorded. The 12V 100Ah model page lists 1,280Wh and 6,000 cycles at 80% depth of discharge, which gives the buyer a baseline for the test.

Rated capacity 70% floor 80% floor Energy at 70% (12.8V) Energy at 80% (12.8V)
100Ah 70Ah 80Ah 896Wh 1,024Wh
200Ah 140Ah 160Ah 1,792Wh 2,048Wh
300Ah 210Ah 240Ah 2,688Wh 3,072Wh

The 70% floor is a minimum, not a target. A pack that reaches 72% at five years passes a 70% policy and fails an 80% policy. Buyers who need the pack to carry a critical load through year five should ask for the higher floor or plan a replacement before the term ends.

The BMS, cells and terminals should be named separately

A warranty that covers “the battery” but excludes the BMS leaves the most common failure point outside cover. The BMS contains the protection board, the balancing circuit and the current sensor. A cell imbalance or a failed protection board can strand a pack that still holds energy. Require each major assembly to be listed by name.

The LINEX warranty policy names BMS failure, protection board faults, cell imbalance and abnormal self-discharge as covered items. That level of detail matters. A policy that says only “manufacturing defects” leaves the buyer to argue about whether a failed BMS is a defect or normal wear.

Component Common failure Should be covered Why it matters
Cells Capacity loss, imbalance, swelling Yes, with a capacity floor Cells are the largest cost in the pack
BMS and protection board Overvoltage, overcurrent or temperature protection failure Yes A failed BMS can disable a healthy pack
Terminals and busbars Corrosion, loose connection, heat damage Yes, if not installer-caused Small part, long downtime
Enclosure and seals Water ingress within the IP rating Yes The IP rating is a product claim
Relay and precharge circuit Welded contact or precharge failure Yes, if fitted Adds cost on rack models

Freight and labor decide the real cost of a claim

A replacement cell or pack is only part of the cost. Return freight, inspection, labor and downtime can exceed the part value on a small 12V pack and can rival it on a rack module. A policy that pays for the part but leaves both freight legs with the buyer is weaker than a shorter policy that covers round-trip freight.

Claim term Buyer pays Supplier pays Practical effect
Round-trip freight Nothing Return and replacement freight Best term for repeat importers
Return freight only Outbound replacement freight Return freight Common middle ground
Both legs Return and replacement freight Nothing Can exceed the part value on small packs
Both legs plus labor Freight and installation labor Nothing Weakest term, treat it as no warranty

Labor is the line most likely to be missing. A 12V 100Ah pack weighs about 10kg and swaps in minutes. A 48V rack module weighs 43kg, needs two people, and may need a technician to recommission the site. Put a labor allowance in writing, or accept that the warranty covers the part and not the downtime.

Proration should be a schedule, not a surprise

A prorated warranty reduces the supplier’s share over time. The schedule should be in the policy, not in a side letter. Epoch’s 11-year policy gives three years of free replacement, then 40% off MSRP on a replacement through Year 11. That is a clear structure: the buyer pays 60% of the list price in the prorated years. A five-year policy can use a simpler split, such as full replacement in Years 1 to 3 and a 50% credit in Years 4 and 5.

Policy structure Years 1 to 3 Years 4 to 5 Buyer share in the final year
Full replacement Part and freight covered Part and freight covered 0%
Part only Part covered Part covered Freight only
50% credit after Year 3 Full replacement 50% credit 50% of the part
40% off MSRP after Year 3 Full replacement 40% discount 60% of MSRP

A proration schedule should state the basis: current list price, original invoice price or a fixed credit. It should also state whether freight is included in the credit. A 50% credit on a part that costs less than the freight is not a useful remedy.

Normal exclusions and red flags look different

Every warranty excludes misuse. The problem is wording that turns normal use into misuse. Physical damage, reverse polarity, water ingress beyond the IP rating, incompatible chargers and unauthorized repair are normal exclusions. A clause that voids the warranty for cycling below 50% depth of discharge is not normal on a LiFePO4 pack rated for 80% depth of discharge.

Normal exclusion Red flag
Physical damage, drops, punctures Warranty void if the battery is cycled below 50% depth of discharge
Reverse polarity or short circuit from incorrect wiring BMS not covered
Water ingress beyond the stated IP rating No capacity coverage; cycle life is not a warranty
Charging with an incompatible or damaged charger Buyer pays freight both ways on every claim
Unauthorized modification or repair Warranty valid only for the original purchaser and non-transferable
Fire, flood or other external events Installation must be by a certified installer, with no certification program

The last red flag can appear in export contracts. A certified-installer clause sounds reasonable until the buyer cannot find a certified installer in the destination country. If the clause is in the warranty, the supplier should publish the certification path and the list of approved installers.

Sourcing LiFePO4 batteries for your market?LINEX supplies 12V-48V lithium batteries, ESS and solar kits - wholesale, OEM/ODM, flexible MOQ.

A claim file should start on installation day

Most rejected claims fail on documentation, not on the battery. Keep the serial number, invoice, shipment date, charger settings and installation photos in one folder. When a fault appears, add the BMS log and a capacity test. A complete file shortens the response and gives the supplier less room to dispute the cause.

Record Why it matters When to capture
Serial number and model code Ties the claim to the shipped unit On receipt
Invoice and shipment date Sets the warranty start On order
Charger and inverter settings Shows the pack ran inside its voltage and current limits On commissioning
Installation photos Documents torque, cable size and enclosure On installation
BMS event log Shows overvoltage, overcurrent or temperature events At fault
Capacity test result Measures remaining Ah against the floor At fault

A capacity test should use the same method the policy names. If the policy is silent, use a 0.2C discharge at 25°C and record the start voltage, end voltage and elapsed time. A test run at a different temperature or a higher C-rate will produce a different result, and the supplier can reject the claim on method alone.

How five years compares with published terms

Term length is the easiest number to compare and the least informative. The table below uses the published documents for three LiFePO4 products. It shows the term, the capacity floor where one is stated, and the replacement structure.

Product Term Capacity floor stated Replacement structure
LINEX LiFePO4 5 years Below 70% of rated value Repair or replace at company option; replacement unit or credit note
EG4 LL-S 10 years Not stated on the spec sheet Not stated on the spec sheet
Epoch SR48100H 11 years 60% end-of-life for the cycle-life test, not a warranty floor 3 years free replacement, then 40% off MSRP through Year 11

The EG4 sheet prints a 10-year warranty and 7,000 deep cycles but does not state a capacity floor. The Epoch page prints an 11-year warranty with a clear proration schedule, while its 60% figure belongs to the cycle-life test at 0.2C and 90% depth of discharge. The LINEX policy prints a 70% floor and a 5-year term. Read the warranty page, not the badge on the spec sheet.

What to put in the purchase contract

Write six terms into the purchase contract: the warranty start date, the capacity floor and test method, the freight and labor split, the replacement or credit remedy, the response and resolution times, and whether the warranty transfers to a reseller or second owner. If the supplier’s standard policy is silent on any of these, the contract term fills the gap.

The LiFePO4 order terms guide covers the commercial side of the same contract. The manufacturer vetting guide covers the factory audit that should come before either document is signed. For the technical baseline, the datasheet guide explains which capacity, current and cycle-life fields to compare, and the 6,000-cycle explainer turns the cycle rating into a service life.

A five-year warranty is a reasonable term for a LiFePO4 pack expected to run 6,000 cycles. It is only useful if the capacity floor, the BMS cover and the freight split are written down. Ask for the warranty document before the proforma invoice, not after the first failure.

Frequently asked questions

Does a five-year warranty cover normal capacity fade?

Only if the remaining capacity falls below the stated floor. Normal fade to 80% or 85% of rated capacity does not trigger a 70% policy. A pack that reaches 69% at year four does.

What does 70% capacity mean in amp-hours?

On a 100Ah pack, 70% of rated capacity is 70Ah. On a 200Ah pack, it is 140Ah. The test should be run at the C-rate and temperature named in the policy, because a fast discharge or a cold test room will lower the measured result.

Is a 10-year warranty always better than a 5-year warranty?

No. A 10-year term with no capacity floor, no BMS cover and buyer-paid freight can cost more than a 5-year term with clear coverage. Compare the floor, the exclusions and the freight split before the term.

Who pays shipping for a warranty claim?

It depends on the policy. Some suppliers cover round-trip freight for a validated claim, some cover the return leg only, and some leave both legs with the buyer. Get the split in writing before the order.

Does the warranty transfer if I sell the battery?

Most limited warranties do not transfer. If you resell packs or change installers mid-project, ask for a transfer clause or a warranty that follows the serial number rather than the original purchaser.

Can I claim without a capacity test?

Most suppliers ask for test data or a BMS log. A claim that says only “the battery does not last” is easy to reject. A 0.2C discharge record with start and end voltages gives the supplier a number to check.

Sources: LINEX warranty policy (5-year limited warranty, capacity below 70% of rated value, BMS and protection board faults, cell imbalance, swelling or leakage, exclusions, 2-business-day response, replacement or credit note, warranty from shipment date, checked 2026-11-11); LINEX 12V 100Ah product page (12.8V, 100Ah, 1,280Wh, 100A continuous, 6,000 cycles at 25°C and 80% DoD, about 10kg, checked 2026-11-11); EG4 LL-S 48V 100Ah spec sheet version 1.2.5 (51.2V, 100Ah, 100A continuous, 7,000 deep cycles, more than 15 years at 80% DoD daily, 10-year warranty, checked 2026-11-11); Epoch SR48100H product page (51.2V, 100Ah, 5.12kWh, 6,000+ cycles at 0.2C and 90% DoD to 60% of initial capacity, 11-year limited warranty with 3 years free replacement then 40% off MSRP through Year 11, checked 2026-11-11); Battery University BU-808 on lithium-ion capacity fade. Last updated 2026-11-11.